A countersunk flat head, a hexalobular socket that keeps the driver engaged under load, and M2 to M10 thread sizes: this stainless steel machine screw combines all three, and that combination is what makes it work on medical equipment housings where nothing may stand proud of the outer surface. The head seats into a matching countersink, the six-lobe recess takes repeated tightening, and the stainless body suits assemblies that are cleaned again and again.
| Specification | Detail |
|---|---|
| Standard | ISO 14581 |
| Screw type | Machine screw |
| Head style | Countersunk flat head |
| Drive | Hexalobular socket (six-lobe) |
| Thread sizes | M2 to M10 |
| Head angles | 82°, 90°, 100°, 110°, 120° |
| Material | Finish |
| Product grade | A |
| Loadability | Reduced loadability, per ISO 14581 Table 3 |
| Finish | Natural stainless, silver tone; passivation confirmed per order |
| Typical assembly | Flush-mounted housings, panels and instrument frames |

The working surface of a countersunk head is its underside: a cone that has to meet a chamfer cut to the same angle, or the head stops on the edge of the hole and never reaches the face. Angles in this family run 82°, 90°, 100°, 110° and 120°, and the one you need is the one your panel is already cut to — send the countersink angle with the enquiry and we confirm the matching part for the size you want, because that list describes the angle family we can discuss rather than a promise that every angle is stocked on every diameter.
Once the angles match, seating depth is set by the countersink itself. A correctly cut chamfer brings the head down until its top face is level with the panel and no further; too deep and the head sinks below the surface, leaving a shallow dish that collects residue, too shallow and it stands proud, which defeats the point of the design. Head diameter follows the screw size, so the countersink has to be cut for that diameter rather than carried over from a neighbouring size.
Thin panels add a second limit. A countersink removes material, and a chamfer deep enough to swallow the head can leave very little wall behind it, so check the remaining thickness under the head before committing to a size. If the panel is thin, say so — a smaller diameter or a different head style, such as a hex socket screw that sits on the surface rather than in it, may suit the joint better than forcing a countersunk screw into thin material.
Replacing an existing flat head screw is mostly a question of matching. A precision fastener is easier to match from a sample than from a description: the countersink angle, the head diameter and the recess size are all visible on the part and hard to put into words. Measure the chamfer, or send the old screw, and the match is settled before anything is ordered.
ISO 14581 covers exactly this family: hexalobular socket countersunk flat head screws in product grade A, with threads from M2 to M10. Built to that document, a stainless steel fastener is compatible with the many medical devices that need a low-profile, recessed drive, and that compatibility is why the standard matters as much as the head shape.
Where a special case needs something the standard does not list, the alternative specifications come from ISO 261, ISO 888, ISO 898-1, ISO 965-2, ISO 3506-1 and ISO 4759-1. Those references are the basis for a variation, not an automatic substitution — if your drawing departs from ISO 14581, tell us which of them the departure is written against.
One substitution to rule out early: ISO 14582 covers high-head countersunk screws in steel, property classes 4.8, 8.8 and 10.9, and those parts are not interchangeable with this countersunk screw because the head heights differ. A joint cut for one will not seat the other, so order against the standard the assembly was designed to.
Screws to this standard come from more than one socket head cap screw manufacturer, and what keeps two of them equal is the standard and the drawing quoted together rather than the description on the order line.
| Thread size | Coarse pitch | Length basis | Typical device joint |
|---|---|---|---|
| M2 | 0.40 mm | Short grip only; the head sits in the cover and the engagement comes from the threaded insert behind it | Display bezels, sensor windows and small cover plates |
| M2.5 | 0.45 mm | Thin plates; get engagement from the mating thread rather than by adding length | Control-panel plates and instrument faceplates |
| M3 | 0.50 mm | Cover thickness plus two to three threads of engagement | Housing covers, bracket feet and stand-off mounts |
| M3.5 | 0.60 mm | Lid and switch joints where the head has to finish level with the plate | Switch plates and small enclosure lids |
| M4 | 0.70 mm | Frame thickness plus engagement; the most common size on a chassis | Chassis frames, arm pivots and panel hinges |
| M5 | 0.80 mm | Heavier plates; check the countersink depth against the wall thickness left behind | Enclosure frames and heavier cover plates |
| M6 | 1.00 mm | Structural joints; grip is set by the frame rather than the cover | Equipment frames, mounting plates and stand joints |
| M8 | 1.25 mm | Long grip; measure over the head and confirm where the thread runs out | Base frames, trolley structures and stand columns |
| M10 | 1.50 mm | Structural grip; the countersink needs a deep chamfer in thick plate | Structural frames and load-bearing housings |
Three lines on the drawing decide what arrives: the steel group, the property class and the passivation route. Under ISO 3506-1 a stainless steel fastener is designated by both — A2 for the 304 family and A4 for the 316 family, then a property class of 50, 70 or 80. The class is what fixes minimum tensile strength, 0.2% proof stress and hardness, and those values are quoted from the standard for the class your drawing names rather than inferred from the word "stainless". Steel property classes such as 4.8, 8.8 and 10.9 belong to a different high-head family, and a joint specified around one of those parts does not transfer over to a countersunk head of the same diameter.
The steel group matters more than the head shape once cleaning enters the picture. Disinfectants carrying chloride, saline residue left to dry on a housing, and repeated wet cycles all attack the 304 family first; the 316 family holds pitting back longer and is the usual choice where a device is wiped down several times a day. The concentration, temperature and dwell time of the cleaning agent change that picture again, which is why the cleaning schedule is worth sending with the enquiry rather than leaving it as "wiped between uses".
Passivation is a separate chemical step after machining, not a property of the steel itself. Two routes are in common use — nitric acid and citric acid — and both work by removing free iron from the surface and rebuilding the chromium oxide layer that gives stainless its corrosion resistance. A part described only as stainless has not necessarily been passivated, so write the route on the drawing and it can be repeated on later batches instead of being left to chance.
A residue or precipitate statement is only worth having if it names the test and the acceptance limit. Ask for the specific method your quality team works to; a general sentence saying the parts are clean cannot be checked and will not survive an audit.
What this screw is not: an implantable or patient-contact component, and it is not supplied sterile. Its working life is inside equipment housings, panels and instrument frames, where the flat head screw stays out of the way of handling and cleaning. Where a fastener passes through a surface a patient touches, or where the device is classified for direct contact, the material and the documentation route are different questions — raise that use at the enquiry stage and it is answered on its own terms rather than folded into an equipment-fastener quotation.
Stainless steel is the fixed part of this specification; the grade is not. Housings are cleaned with different chemistries at different temperatures, so the grade that suits a wiped-down enclosure is not automatically the grade for an instrument that goes through repeat cycles — tell us what the part will meet and we confirm whether the grade you name is the one to quote, rather than supplying a stainless steel fastener that satisfies a drawing but not your cleaning process. Surface condition is agreed the same way. Passivation treatment and any residue or precipitate statement a quality team needs are not published as one figure for every batch, so raise them with the enquiry and they are confirmed for your order instead of being assumed from the material name. A machine screw manufacturer only adds value here if it can hold both the grade and the treatment you name, so the two are confirmed together before the order is accepted. If your drawing calls for a grade we cannot confirm for the size you need, we will say so at quotation rather than substitute quietly.
We provide a Shenzhen-based sourcing and supply service for standard and custom fasteners and electronic hardware. Established in 2010, we work with partner factories to coordinate supplier selection, sampling, quality inspection, customization, consolidation and export delivery. Our five-person team supports your project from design and sample review through mass-production supply, with OEM and ODM orders accepted. We serve customers across Europe, the Americas, Australia and other export markets.